You can find FAQ on how to use AT commands, IP How to have the CDS always log on using a Mobile IP perfered "MIP" programming telephone # for all models . Good source to find options and understanding SMS messaging used for industrial controls application. Understanding CDMA Always on connection and dial-up connection.


FAQ(s) found under  Setup & Configuration Showing 24 Of 29 Prev  |  Next

Quick setup for the GSM CDS-1900 - How do I activate the CDS-1900?
Date Add : 2007-10-27 

Views : 2737

 Printer Version

  Tell A Friend

  Email Link To Me

Enrique
1900 modem
  • Get Sim Card
    • Call AT&T "Schuyler Roberts" (805-395-0478 or cellular 805-395-0478)
      • “schuyler.roberts@cingular.com”
      • request a mobile terminated connection SIM with a DATA PLAN
      • You will receive a SIM card with a telephone # and a 20 digit SIM #
      • You will be issued an IMIE #
      • Call 888-444-4410 to activate the Modem.
  • Connect to the Modem via the RS232 cable. Set the port for 115,200 baud rate.
  • Type AT. The response will be
  • Type AT+XCNFG? response will be the current configuration
  • Type AT+XCNFG=2,1,”internet” This changes the APN (Access point name”
  • Type AT+XCNFG=1,1,”Modem Phone number”
  • Re-start the modem
  • AT+XSTAT reports the current IP address
  • Typing the following command in the CMD prompt of a Windows machine will give you the current IP address of the telephone number
  • To change the baud rate
    • AT+IPR? this returns the current baud rate
    • AT+IPR=38400 sets to 38400
  • Setup the reporting of the unit’s IP address (UDP)
    • AT+XCNFG=6,2 < IP current>
    • AT+XCNFG=7,2 current port
    • AT+XCNFG=6,1,”76.12.35.241”
    • AT+XCNFG=7,1,”4001”
  • Setup the reporting of the LAT/LONG (UDP)
    • AT+XCNFG=10,2 < IP current>
    • AT+XCNFG=11,2 current port
    • AT+XCNFG=10,1,”76.12.35.241”
    • AT+XCNFG=11,1,”3001”
  • Set UP the reporting time of the LAT/LONG
    • AT+XCNFG=21,1,600 This sets the reporting time to every 60 seconds
      • This value is expressed as 100 msec increments




Your Rating :

Related FAQs In This Category
• Does the CDS products have Modem Emulation mode
for spoofing software?
• CDS-9022\9060 has 16 pin header. I need to know how to get the cryout SMS\Email alarms working, which pins are inputs and which are outputs. thank you in advance.


Submit Questions / Post Inquiries
If your question have not been answered, or if you would like to send us an inquiry, please click here

Most Popular Questions

• When is Analog Cellular going away????
   Replace your Analog Cellular Data unit’s before it’s too late!      ...
   Views : 12005       Last Update : 2007-08-08


• I received "No Carrier" after dialing ATDT+Phone Number within 4 seconds, what does that mean?
   Check with your CDMA Provider to "make sure that your number is provisioned correctly.   ...
   Views : 7403       Date Add : 2007-03-29    


• CDS-9022\9060 has 16 pin header. I need to know how to get the cryout SMS\Email alarms working, which pins are inputs and which are outputs. thank you in advance.


      Pin-out 9022 P7 \ 9060 P2 1 = Input 0    2 = GND  3 = Input 1 &n...
   Views : 7341       Last Update : 2007-03-14


Latest Added FAQs

• How do I find pin 1 for the I/O Pigtail cable?
   Pin 1 is noted on the diagram below, Pin 1 on the 9060 is the top right pin -- Diagram --  ...
   Views : 15       Date Add : 2010-09-01    


• How do I setup IP-COM \ IP-Manager ComPort Redirector Software for Windows. Converts modem applications to work over TCP/UDP/IP network.

VirtualComm IP Manager. This innovative software can communicate seamlessly with old communications software and divert data out of a virtual serial port rather than through the traditional physical serial port. This virtual serial port emulates the physical communication port and provides a digital gateway to the internet—all without requiring any modification to the existing software codes or other equipment. The VirtualComm IP Manager works as a circuit-switched call, but is actually internet based.

   See how it works http://76.12.35.241/dataremote/ipmanager/ipmanager.html   Features ...
   Views : 1961       Last Update : 2008-08-14


• Hi, I require a CDMA modem to run off 24VDC and be used in remote applications where a serial interface is required. Most importantly, I need the modem to be compatible with the following serial port parameters - Baud 115200, Data Bits 7, Par ity Even and 1 stop bit. Please let me know which modem will allow this. Thanks in advance. M2M text messaging using Data Bits of 7,E,1 @ 115200bps
   Yes our modem does everything your asking for! Please look at the CDS-9060  http://www.datarem...
   Views : 2305       Date Add : 2008-06-04    


Technical Support

Warranty & Return Policy



Download User Manuals and Spec Sheets

Download User Manuals

Download Software & Drivers

Download Software & Drivers.

Contact DataRemote's Tech Support Team

Contact Technical Support

Browse Our Online Store

Browse Our Online Store




Browse by Category
Setup & Configuration (29)
Setting up and configuring your DataRemote Modems

Troubleshooting (21)
Troubleshooting your DataRemote Modems.

Tutorials (2)
Tutorials for setup and configuration of your DataRemote Wireless Modems.

Terminology (4)
Commonly used terms associated with the Cellular Industry


© 2010 DateRemote Inc. All Rights Reserved - Privacy Policy/Terms | Web Design by GlobalWebFX.com