You can find FAQ on how to use AT commands, IP How to have the CDS always log on using a Mobile IP perfered "MIP" programming telephone # for all models . Good source to find options and understanding SMS messaging used for industrial controls application. Understanding CDMA Always on connection and dial-up connection.


FAQ(s) found under  Setup & Configuration Showing 20 Of 29 Prev  |  Next

What is the Pin-Out for the CDS modems DB-9?


Part# DRA-RS232
Last Update : 2007-06-05 

Views : 4666

 Printer Version

  Tell A Friend

  Email Link To Me

Pin-Out for the CDS modems DB-9 Wiring diagram. The CDS is wire as a DCE device. When wiring a DCE to DTE its pin to pin. If you don’t want to solder your cable please see our DB-9 to terminal block converter Part# DRA-RS232                                  

SerialPort Pinouts
DB-9 (9 pin)                                 pin assignments
DB-9 Pin
 
Signal
Function
1
 
CD
Carrier Detect
2
 
RD
Receive Data
3
 
TD
Transmit Data
4
 
DTR
Data Terminal Ready
5
 
SG
Signal Ground
6
 
DSR
Data Set Ready
7
 
RTS
Request To Send
8
 
CTS
Clear To Send

 Note: when using a 3 wire connection with the CDS units you don’t need to add jumpers or add AT-Commands. The CDS will automatically use NO FLOW CONTROL.





Your Rating :

Related FAQs In This Category
• I’m using the CDS-9060 hook via RS-232 to a PLC I call into the unit from a landline modem. I want to know if the CDS-9060 Cellular modem has AT-Commands that can be used to LOG onto the internet in TCP or UDP mode? I’m wanting to dial from a host computer into a IP address\CDS modem Communicating to a PLC\RTU .

Thanks in advance,
Bill Thornwhite
Control Systems
Richmond, TX
• What is the normal baud rate of data transmission with all alternative rates
available?

Submit Questions / Post Inquiries
If your question have not been answered, or if you would like to send us an inquiry, please click here

Most Popular Questions

• When is Analog Cellular going away????
   Replace your Analog Cellular Data unit’s before it’s too late!      ...
   Views : 12018       Last Update : 2007-08-08


• I received "No Carrier" after dialing ATDT+Phone Number within 4 seconds, what does that mean?
   Check with your CDMA Provider to "make sure that your number is provisioned correctly.   ...
   Views : 7413       Date Add : 2007-03-29    


• CDS-9022\9060 has 16 pin header. I need to know how to get the cryout SMS\Email alarms working, which pins are inputs and which are outputs. thank you in advance.


      Pin-out 9022 P7 \ 9060 P2 1 = Input 0    2 = GND  3 = Input 1 &n...
   Views : 7347       Last Update : 2007-03-14


Latest Added FAQs

• How do I find pin 1 for the I/O Pigtail cable?
   Pin 1 is noted on the diagram below, Pin 1 on the 9060 is the top right pin -- Diagram --  ...
   Views : 16       Date Add : 2010-09-01    


• How do I setup IP-COM \ IP-Manager ComPort Redirector Software for Windows. Converts modem applications to work over TCP/UDP/IP network.

VirtualComm IP Manager. This innovative software can communicate seamlessly with old communications software and divert data out of a virtual serial port rather than through the traditional physical serial port. This virtual serial port emulates the physical communication port and provides a digital gateway to the internet—all without requiring any modification to the existing software codes or other equipment. The VirtualComm IP Manager works as a circuit-switched call, but is actually internet based.

   See how it works http://76.12.35.241/dataremote/ipmanager/ipmanager.html   Features ...
   Views : 1966       Last Update : 2008-08-14


• Hi, I require a CDMA modem to run off 24VDC and be used in remote applications where a serial interface is required. Most importantly, I need the modem to be compatible with the following serial port parameters - Baud 115200, Data Bits 7, Par ity Even and 1 stop bit. Please let me know which modem will allow this. Thanks in advance. M2M text messaging using Data Bits of 7,E,1 @ 115200bps
   Yes our modem does everything your asking for! Please look at the CDS-9060  http://www.datarem...
   Views : 2307       Date Add : 2008-06-04    


Technical Support

Warranty & Return Policy



Download User Manuals and Spec Sheets

Download User Manuals

Download Software & Drivers

Download Software & Drivers.

Contact DataRemote's Tech Support Team

Contact Technical Support

Browse Our Online Store

Browse Our Online Store




Browse by Category
Setup & Configuration (29)
Setting up and configuring your DataRemote Modems

Troubleshooting (21)
Troubleshooting your DataRemote Modems.

Tutorials (2)
Tutorials for setup and configuration of your DataRemote Wireless Modems.

Terminology (4)
Commonly used terms associated with the Cellular Industry


© 2010 DateRemote Inc. All Rights Reserved - Privacy Policy/Terms | Web Design by GlobalWebFX.com