| FAQ(s) found under Troubleshooting | Showing 6 Of 21 | Prev | Next |
| CDS-9022\9060 has 16 pin header. I need to know how to get the cryout SMS\Email alarms working, which pins are inputs and which are outputs. thank you in advance. | ||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||
Pin-out 9022 P7 \ 9060 P2
1 = Input 0
2 = GND 3 = Input 1 4 = Input 2 5 = Input 3 Cry-out alarm SMS 1 “Active Low” 6 = Input 4 7 = VCC “Do Not use” 8 = Input 5 9 = Output 0 10 = N/A 11 = Output 1 12 = Output 2 13 = Output 3 14 = Output 4 15 = Output 5 16 = GND - I/O connector, Input 3 [pin 5] and Input 5 [pin 8] is momentarily shorted for at least 1 seconds to GND, the modem automatically switches to SMS mode and delivers the message, and then switches back to data mode. Please note that there are time durations of approximately 20 seconds that occur while switching from data to SMS modes and back again. Sample - ************** ALARM SETUP MENU ************* A - SMS Address 1 : 8056601276 Select Option:
Option
Parameter
Description
A
SMS Address 1
Enter the cell phone number of the phone that is to receive text messages from the modem. "Message 1" B
SMS Address 2
Enter the email address that is to receive text messages from the modem. "Message 1" C
SMS Address 3
SMS or Email address that is to receive text messages from the modem. "Message 1" D
SMS Address 4
SMS or Email address that is to receive text messages from the modem. "Message 2" E
SMS Address 5
SMS or Email address that is to receive text messages from the modem. "Message 2" F
SMS Address 6
SMS or Email address that is to receive text messages from the modem. "Message 2" G
Voice Dial Number
Enter a voice number that the modem will call when an alarm is triggered.
H
Alarm Message 1 - 3
Enter the message to be sent when an alarm is triggered on input 0"see I/O setup"
I
Alarm Message 4 - 6
Enter the message to be sent when an alarm is triggered on input 1."see I/O setup"
Attachment : p7input_iopinout.pdf |
| Related FAQs In This Category |
| • What is the Pin-Out for the CDS modems DB-9? Part# DRA-RS232 |
| • How Do I Perform An Over-the-Air Activation Of The Unit? |
| Submit Questions / Post Inquiries |
| If your question have not been answered, or if you would like to send us an inquiry, please click here |
| Most Popular Questions |
| • When is Analog Cellular going away???? Replace your Analog Cellular Data unit’s before it’s too late! ... Views : 12018   Last Update : 2007-08-08 |
| • I received "No Carrier" after dialing ATDT+Phone Number within 4 seconds, what does that mean? Check with your CDMA Provider to "make sure that your number is provisioned correctly. ... Views : 7413   Date Add : 2007-03-29 |
| • CDS-9022\9060 has 16 pin header. I need to know how to get the cryout SMS\Email alarms working, which pins are inputs and which are outputs. thank you in advance. Pin-out 9022 P7 \ 9060 P2 1 = Input 0 2 = GND 3 = Input 1 &n... Views : 7346   Last Update : 2007-03-14 |
| Latest Added FAQs |
| • I'm Programming a CDS-9060 with a SPRINT # and the MDN is different then the MIN. Ever time I tell it to program it defaults back to the MIN. Why is this happening and is there a fix? For some reason when programming some Sprint numbers that have 2 different numbers for the MIN and M... Views : 2377   Date Add : 2008-06-13 |
| • How do I test the CDS-9060-TR to make sure the internal modem and local loop is working properly? The attached file will test the RJ-11 Tip and Ring function and the internal Analog modem. &nbs... Views : 2259   Date Add : 2007-05-29 |
| • Does the CDS products have Modem Emulation mode for spoofing software? Modem Emulation mode -The CDS modems act like a Dialup\Dial-outbound standard Hayes AT-Compatib... Views : 5696   Last Update : 2007-10-13 |


| Browse by Category | |
| Setup & Configuration (29) Setting up and configuring your DataRemote Modems | |
| Troubleshooting (21) Troubleshooting your DataRemote Modems. | |
| Tutorials (2) Tutorials for setup and configuration of your DataRemote Wireless Modems. | |
| Terminology (4) Commonly used terms associated with the Cellular Industry | |